Envelope defects are invisible until they're expensive: air leakage, thermal bypasses, wet insulation. Atlas turns a thermal survey of walls, roofs, and junctions into documented, measured findings that support retrofit scopes and construction-defect claims alike.
For envelope consultants and energy professionals
Rigorous thermography workflows for the building science crowd.
Calibrated temperature analysis
Inspect per-pixel temperatures, adjust emissivity and reflected temperature, and place spot and area measurements that update live as you tune parameters.
Radiometric file support
Atlas reads the calibrated temperature data embedded in DJI R-JPEG and FLIR radiometric files — not just the colorized preview — so every reading is a measurement, not a guess.
Annotation & markup
Drop pins with live temperature readouts, mark regions, add delta-T callouts, and attach field notes so every finding carries its evidence.
Mobile field capture
The companion mobile app captures photos, notes, and flight details on site and syncs them straight into the right project.
Branded PDF reports
Generate client-ready reports with annotated imagery, findings tables, and severity grading — under your logo and brand, ready to send the same day.
Secure client share links
Share findings through expiring, optionally passphrase-protected links. Clients review imagery and comments in the browser — no account required.
Defect signatures, quantified
Thermal bridging at a slab edge, convective looping in a wall cavity, and missing batts each have a distinct pattern — but a credible report quantifies them. Atlas gives you calibrated surface temperatures, adjustable emissivity per material, and area statistics so the anomaly you describe comes with the delta-T that proves it.
Interior and exterior, one survey record
Envelope work mixes exterior drone passes with interior handheld captures. Atlas accepts both, organizes them under one project, and pairs findings across the assembly — the cold streak on the interior gypsum matched with the exterior view of the same bay. Field notes captured on the mobile app land in the same record.
Frequently asked questions
What envelope defects show up in thermal surveys?
Air leakage paths, missing or slumped insulation, thermal bridging, moisture in assemblies, and failed glazing seals — each visible as a characteristic surface-temperature pattern under the right conditions.
What conditions does an envelope thermal survey need?
A meaningful inside-outside temperature difference (commonly 10°C/18°F or more) and stable conditions. Atlas logs survey timing and site weather so your report documents that conditions were valid.
Can Atlas support blower-door-assisted surveys?
Yes — capture imagery during depressurization and document the sequence in the project record. The pressure equipment is yours; the imagery, measurement, and reporting side is Atlas.